Discover custom decorative fan coil units that blend HVAC performance with modern interior design. Conceal bulky hardware and optimize comfort.
Compare high wall vs floor standing fan coil units to optimize HVAC design. Explore the MECO MFP-68BM-C for efficient, space-saving cooling.
Discover the MECO Auto Swing Fan Coil Unit. Eliminate hot and cold spots with quiet, energy-efficient, remote-controlled climate control.
Discover the MECO High Wall Mounted Fan Coil Unit for quiet, safe, and efficient climate control in hotels, apartments, and production spaces.
Discover how a chilled water split type fan coil unit provides efficient, low-noise HVAC climate control for commercial and residential spaces.
Discover the MECO decorative fan coil unit. This sleek, ultra-slim 145mm system delivers quiet, efficient heating and cooling for modern interiors.
Upgrade your space with decorative fan coil units blending modern aesthetics and powerful climate control. Discover the quiet, efficient MECO model.
Discover decorative fan coil units that blend high-end design with climate control. Explore slim, low-noise HVAC solutions for modern interiors.
Specify fan coil units with confidence. Guide to acoustics, EC motors, and drainage to prevent costly HVAC failures and optimize comfort.
Compare fan coil units vs air handling units: a vendor-neutral framework to select the right HVAC system for zoning, IAQ, and cost—avoid over-engineering or inadequate ventilation.
Struggling with HVAC changeover seasons? Our 2-pipe vs 4-pipe fan coil comparison reveals how to balance upfront cost and long-term tenant comfort.
Ceiling concealed vs cassette fan coil units: compare aesthetics, acoustics, & maintenance to select the perfect HVAC for your commercial space.
Cut hotel HVAC noise with data-driven specs, not marketing claims. Learn acoustic metrics and low-noise fan coil selection for silent rooms.
Water leakage from ceiling-mounted HVAC equipment is a building manager's nightmare. A single drip can stain expensive ceiling tiles, damage interior finishes, create slip hazards, and lead to mold growth that affects indoor air quality. For commercial spaces such as hotels, offices, hospitals, and
In a hospital environment, the HVAC system is not merely a matter of occupant comfort—it is a critical component of infection prevention. Nowhere is this more true than in clean rooms, operating theaters, intensive care units (ICUs), isolation wards, and pharmaceutical preparation areas. For these s
Selecting the optimal location for a Floor Standing Concealed Type Fan Coil Unit is one of the most critical decisions in any HVAC system design. The placement of these units directly affects thermal comfort, energy efficiency, equipment longevity, maintenance accessibility, and even property aesthe
How to Clean the Drain Pan of a Concealed Fan Coil Unit?A water stain spreading across a ceiling tile is one of the most dreaded sights for any facility manager or building owner. In hotels, office buildings, hospitals, and residential complexes, water dripping from a Concealed Fan Coil Unit not onl
How to Reduce Vibration Noise in Ducted Fan Coil Units?Excessive vibration noise from a Ducted Fan Coil Units is one of the most frequent complaints in commercial and residential HVAC systems. In hotels, office buildings, hospitals, and apartment complexes, constant rattling, humming, or rumbling fr
Selecting the correct static pressure is one of the most critical—but often misunderstood—steps when designing an HVAC system using a ceiling conceal duct type fan coil unit. In commercial buildings, hotels, hospitals, offices, and residential developments, these units are widely used for their quiet operation, space-saving installation, and flexible air distribution. However, even the most advanced fan coil unit cannot perform as intended if static pressure is improperly selected.
When an HVAC project falls behind schedule, the reason is rarely the equipment alone—it’s the installation details that quietly add hours, create rework, and increase commissioning risk. In many commercial and residential developments, the ceiling conceal duct type fan coil unit is chosen specifically because it delivers comfortable, quiet air distribution while keeping the mechanical system out of sight. But concealment has a trade-off: installers work in tight ceiling voids, coordinate with multiple trades, and fight for every millimeter of clearance.
| Availability: | |
|---|---|
| Quantity: | |
MFP-170ZDM
MECO
The MFP-170ZDM is a ceiling and floor mounted fan coil unit designed for spaces that require flexible installation arrangements. This unit supports three mounting methods: ceiling-mounted, floor-standing, and high wall-mounted, allowing project managers to select the configuration that matches the interior layout and architectural constraints of each room. The multi-mount design reduces the need for different product SKUs across a single project, simplifying procurement and inventory management for commercial applications.
The unit features a streamlined rectangular casing with integrated air intake grilles and a frontal air discharge slot. The exterior casing uses a white powder-coated finish, compatible with most standard ceiling and wall color schemes in office buildings, hotels, and healthcare facilities.
The MFP-170ZDM delivers the following thermal performance under standard test conditions:
Parameter | Value | Unit |
Cooling capacity (high speed) | 30708 | BTU/h |
Cooling capacity (total heat, high) | 6746 | W |
Cooling capacity (sensible heat, high) | 23017 | W |
Heating capacity (high speed) | 13500 | W |
Heating capacity (medium speed) | 10557 | W |
The unit operates across three fan speed settings with corresponding airflow and static pressure ratings:
Parameter | High | Medium | Low | Unit |
Air volume | 1360 | 1280 | — | m³/h |
External static pressure | 0 | — | — | Pa |
Acoustic and electrical performance data by fan speed:
Parameter | High | Medium | Low | Unit |
Noise level | 48 | — | — | dB(A) |
Power input | 152 | 148 | — | W |
The coil assembly uses hydrophilic aluminum fins mechanically bonded to copper tubes. This configuration provides a measured heat exchange surface area optimized for balanced airflow and thermal transfer. The maximum working pressure of the coil is 1.6 MPa, making the unit suitable for installations with variable water pressure conditions.
The unit is equipped with a centrifugal fan assembly with three selectable speed settings. The motor and fan combination is calibrated to deliver the rated air volume while maintaining the published noise levels.
Both inlet and outlet water connections use ZG3/4" threaded ports. The pressure drop across the coil at rated flow is 32 kPa. The unit includes a condensate drain pan with a 26 mm drain connection for removal of condensed water during cooling operation.
The MFP-170ZDM ships with a remote controller as the standard control interface. Additional controller types are available as options to match different project requirements. The unit can be integrated with most widely used building management systems that support the Modbus communication protocol, enabling centralized monitoring and control across commercial facilities.
This ceiling floor mounted fan coil unit is specified for a range of commercial and institutional spaces including hotel guest rooms, private offices, hospital patient rooms, retail boutiques, and classroom environments. The three mounting options allow engineers to specify a single model across rooms with different ceiling heights and interior layouts.
The unit supports three installation configurations: ceiling-mounted, floor-standing, and high wall-mounted. Project teams can select the mounting method based on available space and interior design requirements.
The heat exchanger coil has a maximum working pressure rating of 1.6 MPa.
Yes, the MFP-170ZDM can interface with building management systems that use the Modbus protocol.
Both the water inlet and outlet ports use ZG3/4" threaded connections.