Discover custom decorative fan coil units that blend HVAC performance with modern interior design. Conceal bulky hardware and optimize comfort.
Compare high wall vs floor standing fan coil units to optimize HVAC design. Explore the MECO MFP-68BM-C for efficient, space-saving cooling.
Discover the MECO Auto Swing Fan Coil Unit. Eliminate hot and cold spots with quiet, energy-efficient, remote-controlled climate control.
Discover the MECO High Wall Mounted Fan Coil Unit for quiet, safe, and efficient climate control in hotels, apartments, and production spaces.
Discover how a chilled water split type fan coil unit provides efficient, low-noise HVAC climate control for commercial and residential spaces.
Discover the MECO decorative fan coil unit. This sleek, ultra-slim 145mm system delivers quiet, efficient heating and cooling for modern interiors.
Upgrade your space with decorative fan coil units blending modern aesthetics and powerful climate control. Discover the quiet, efficient MECO model.
Discover decorative fan coil units that blend high-end design with climate control. Explore slim, low-noise HVAC solutions for modern interiors.
Specify fan coil units with confidence. Guide to acoustics, EC motors, and drainage to prevent costly HVAC failures and optimize comfort.
Compare fan coil units vs air handling units: a vendor-neutral framework to select the right HVAC system for zoning, IAQ, and cost—avoid over-engineering or inadequate ventilation.
Struggling with HVAC changeover seasons? Our 2-pipe vs 4-pipe fan coil comparison reveals how to balance upfront cost and long-term tenant comfort.
Ceiling concealed vs cassette fan coil units: compare aesthetics, acoustics, & maintenance to select the perfect HVAC for your commercial space.
Cut hotel HVAC noise with data-driven specs, not marketing claims. Learn acoustic metrics and low-noise fan coil selection for silent rooms.
Water leakage from ceiling-mounted HVAC equipment is a building manager's nightmare. A single drip can stain expensive ceiling tiles, damage interior finishes, create slip hazards, and lead to mold growth that affects indoor air quality. For commercial spaces such as hotels, offices, hospitals, and
In a hospital environment, the HVAC system is not merely a matter of occupant comfort—it is a critical component of infection prevention. Nowhere is this more true than in clean rooms, operating theaters, intensive care units (ICUs), isolation wards, and pharmaceutical preparation areas. For these s
Selecting the optimal location for a Floor Standing Concealed Type Fan Coil Unit is one of the most critical decisions in any HVAC system design. The placement of these units directly affects thermal comfort, energy efficiency, equipment longevity, maintenance accessibility, and even property aesthe
How to Clean the Drain Pan of a Concealed Fan Coil Unit?A water stain spreading across a ceiling tile is one of the most dreaded sights for any facility manager or building owner. In hotels, office buildings, hospitals, and residential complexes, water dripping from a Concealed Fan Coil Unit not onl
How to Reduce Vibration Noise in Ducted Fan Coil Units?Excessive vibration noise from a Ducted Fan Coil Units is one of the most frequent complaints in commercial and residential HVAC systems. In hotels, office buildings, hospitals, and apartment complexes, constant rattling, humming, or rumbling fr
Selecting the correct static pressure is one of the most critical—but often misunderstood—steps when designing an HVAC system using a ceiling conceal duct type fan coil unit. In commercial buildings, hotels, hospitals, offices, and residential developments, these units are widely used for their quiet operation, space-saving installation, and flexible air distribution. However, even the most advanced fan coil unit cannot perform as intended if static pressure is improperly selected.
When an HVAC project falls behind schedule, the reason is rarely the equipment alone—it’s the installation details that quietly add hours, create rework, and increase commissioning risk. In many commercial and residential developments, the ceiling conceal duct type fan coil unit is chosen specifically because it delivers comfortable, quiet air distribution while keeping the mechanical system out of sight. But concealment has a trade-off: installers work in tight ceiling voids, coordinate with multiple trades, and fight for every millimeter of clearance.
| Availability: | |
|---|---|
| Quantity: | |
Features
1. Surround air flowing which can substantially reduce the non-blowing area.
2. Remote controller is standard and wire controller is optional
3. Auto swing
4 Fresh air can be input from outside
Our advantages
1. The dimension of G1 unit is only 570*570mm.Thin design units which can be installed in a limit ceiling (the Min. Thickness is 240mm)
2. Adopting a large diameter turbo centrifugal fan for low noise operation.
3. Specially panel design to avoid air-short flowing.
4. Excellent Performance-Integral C type heat exchanger, blue fin
5. Air-cleaning function can be selected; we offer negative ion generator as optional parts.
6. Water pump is build-in, and the float switch inside to prevent from leaking
7. 4-tube system is optional
8. Square panels, which can choose the direction of inlet/outlet water connection freely.
Product Applications
Recommended places of use: supermarkets, restaurants, offices, meeting rooms, lobbies, and other high-end places.
| TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | ||||||||||||
| PERFORMANCE OF CASSETTE TYPE FAN COIL(Surround air flowing,2 TUBE) | ||||||||||||
| H | H | MFP-34KM-(Q)KG1 | MFP-51KM-(Q)KG1 | MFP-68KM-(Q)KG1 | MFP-85KM-(Q)KG1 | MFP-102KM-(Q)GG3 | MFP-136KM-(Q)GG3 | MFP-170KM-(Q)GG3 | MFP-204KM-(Q)GG3 | MFP-238KM-(Q)GG3 | ||
| MODEL OF UNIT | MFP-34KM-(Q)K1 | MFP-51KM-(Q)K1 | MFP-68KM-(Q)K1 | MFP-85KM-(Q)K1 | MFP-102KM-(Q)G3 | MFP-136KM-(Q)G3 | MFP-170KM-(Q)G3 | MFP-204KM-(Q)G3 | MFP-238KM-(Q)G3 | |||
| MODEL OF PANEL | MB-S****G1 | MB-S****G3 | ||||||||||
| POWER SUPPLY | 220V,50Hz,1Ph | |||||||||||
| air volume | H | m3/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
| M | 280 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | |||
| L | 180 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | |||
| static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| cooling capacity | TH | H | W | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
| BTU/h | 6142 | 9212 | 12283 | 15354 | 18425 | 24566 | 30708 | 36850 | 42991 | |||
| SH | W | 1311 | 1971 | 2700 | 3184 | 4196 | 5362 | 6707 | 8072 | 9070 | ||
| BTU/h | 4473 | 6725 | 9212 | 10864 | 14317 | 18295 | 22884 | 27542 | 30947 | |||
| TH | M | W | 1500 | 2460 | 3000 | 3715 | 4423 | 6435 | 7848 | 9296 | 10500 | |
| W | 994 | 1555 | 1995 | 2426 | 3041 | 4236 | 5393 | 6603 | 7190 | |||
| SH | L | W | 1391 | 2057 | 2479 | 2921 | 3793 | 5604 | 7223 | 8534 | 8900 | |
| W | 823 | 1200 | 1530 | 1826 | 2373 | 3284 | 4416 | 5248 | 5500 | |||
| heating capacity | H | W | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | |
| M | W | 1949 | 2770 | 3938 | 4902 | 5694 | 7924 | 10473 | 12997 | 13900 | ||
| L | W | 1297 | 1774 | 2779 | 3505 | 3876 | 5421 | 6992 | 8645 | 9700 | ||
| noise | H | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 51 | |
| power input | H | W | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |
| waterflow volume | m3/h | 0.31 | 0.46 | 0.62 | 0.77 | 0.93 | 1.23 | 1.54 | 1.85 | 2.16 | ||
| water pressure dropping | kPa | 11.8 | 11.8 | 22.4 | 27 | 29.6 | 29.6 | 35.4 | 35.4 | 40 | ||
| dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
| out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
| coil | type | |||||||||||
| The maximum pressure | MPa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | ||
| dimension of water drain pipe | mm | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ||
| unit dimennsion | UNIT | L×W×H mm | 570*570*290 | 840*840*240 | 840*840*285 | |||||||
| PANEL | 650*650*30 | 950*950*45 | ||||||||||
| WEIGHT | UNIT | kg | 19 | 19 | 20 | 21 | 24 | 25 | 28 | 28 | 30 | |
| PANEL | 2 | 6 | 6 | |||||||||