Are you considering installing a high wall mounted unit but wondering about its power consumption? In this article, we will explore the various factors that can affect the power consumption of these units, as well as the benefits they offer in terms of energy efficiency. Additionally, we will provide you with some practical tips on how to further reduce power consumption when using high wall mounted units.
In today's fast-paced world, efficiency and convenience are key factors in any industry. When it comes to installing water valves, integrating them into existing systems can provide a wide range of benefits. From streamlining the installation process to improving overall functionality, the advantages of water valve integration are numerous.
In today's digital age, the use of digital display panels has become increasingly prevalent in enhancing user experience across various industries. From retail stores to airports, understanding the technology behind these panels is crucial for businesses looking to stay ahead of the curve. By utilizing digital display panels, businesses can create engaging and interactive experiences for their customers, ultimately leading to increased brand loyalty and customer satisfaction.
Condensate leakage can be a common issue with traditional HVAC systems, leading to potential damage and inefficiencies. However, with the advancements in technology, 4-Way Cassette Units have emerged as a solution to effectively prevent condensate leakage. Through innovative design features such as improved drainage systems and advanced sensors, these units offer a reliable and efficient cooling solution for both residential and commercial spaces.
Fan coil units are ideal end products for central air conditioning, widely used in hotels, office buildings, hospitals, commercial and residential areas, and research institutions. It is understood that in order to meet the design requirements of different occasions. Fan coil units should be install
First, the definition of two and three lines of the electric valve1. The second line of the electric valve: the two wires of the electric valve are the control signal input line and the power cord.2. Three lines of the electric valve: the three lines of the electric valve are respectively the contro
In the air conditioning system, fan coil is a common hot and cold water heat exchanger, mainly used in indoor air conditioning systems. The three-way valve is one of the important components in the air conditioning system, which is used to control the flow direction and flow of hot and cold water. T
In the world of industrial equipment and electronics, achieving quiet operation is often a top priority for manufacturers. One key component that can greatly contribute to this goal is the integration of cross flow fans. In this article, we will explore the benefits of cross flow fan integration, including improved airflow and reduced noise levels. We will also discuss important factors to consider when integrating cross flow fans, such as size, power consumption, and installation requirements.
Are you looking to improve the air circulation in your home or office? One way to achieve this is through the use of the auto swing feature in your air conditioning unit. In this article, we will explore the benefits of this innovative feature, including how it enhances comfort and efficiency, as we
Are you considering incorporating ultra thin type units into your interior design but unsure if they will complement your style? In this article, we will explore the benefits of ultra thin type units, discuss key factors to consider for compatibility with different interior styles, and present case studies showcasing how these sleek units can seamlessly blend in various design aesthetics.
In the world of marketing, understanding the concept of Host Linkage Function is crucial for businesses looking to optimize convenience and control in their operations. From its features to best practices for utilization, this article delves into the intricacies of Host Linkage Function, providing valuable insights for marketers seeking to leverage this function effectively.
The central air conditioning system consists of three parts: air ducts, air duct accessories and components, and end equipment and components of the air conditioning system.
Aluminum zinc plates have become increasingly popular in various industries due to their numerous benefits and applications. In this article, we will explore the advantages of using aluminum zinc plates, such as their exceptional durability and resistance to corrosion. We will also delve into the wi
The overflow of condensate from fan coil units is a common malfunction of centralized air conditioning systems in summer, which often occurs in hot and humid weather and can cause unnecessary damage to air-conditioned rooms.
When it comes to selecting the right DC motor for your application, longevity and performance are two crucial factors to consider. Understanding the key features that contribute to both longevity and performance can help you make an informed decision. In this article, we will explore the standard fe
In the world of modern appliances, space-saving design has become a key consideration for consumers. One innovative solution that has gained popularity is the integration of drain pumps into various home appliances. This article explores the numerous advantages of drain pump integration, focusing on
Are you looking for cost-effective solutions for your installation projects? Optional 3-way valves could be the answer you've been searching for. In this article, we will explore the advantages of using optional 3-way valves, including increased efficiency, reduced maintenance costs, and improved co
Availability: | |
---|---|
Quantity: | |
MFP-68FM, MFP-85FM, MFP-272FM, MFP-300FM
MECO
8415909000, 8415901000
Features
1. Four side air blowing, which can uniform temperature distribution in the room
2. Electrostatic dust sanitizer is optional
3 Fresh air can be input from outside
4 Standard with brushless DC motor
5 Can connect to duct and link with diffuser
Our advantages
1 Customizable metal grille air inlet design, easy to fit with the decoration style.
2 All the key parts are easy to maintain from the air inlet grille
3 The models with big air volume is good for the projects which have large space
Product Applications
If product is installed in spaces with suspended ceilings, such as offices, it can have four air outlets connected to air ducts to supply air to different rooms. In spaces without suspended ceilings, such as factories and workshops, installation without ducts can be used. This product has a long air supply distance, uniform airflow organization, and low installation cost.
TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | |||||||
PERFORMANCE OF 4-SIDE AIR FLOWING TYPE FAN COIL | |||||||
model(2 tube system) | DC-MFP-68FM-Q | DC-MFP-85FM-Q | DC-MFP-272FM-Q | DC-MFP-300FM-Q | |||
power supply | 220V~,50Hz | ||||||
air volume | H | m3/h | 680 | 850 | 2720 | 3000 | |
M | 520 | 660 | 2040 | 2300 | |||
L | 370 | 430 | 1360 | 1600 | |||
static pressure | Pa | 0 | 0 | 0 | 0 | ||
cooling capacity | TH | H | W | 3800 | 4700 | 15000 | 17000 |
BTU/h | 12966 | 14767 | 47130 | 53414 | |||
SH | W | 2830 | 3500 | 11175 | 12665 | ||
BTU/h | 9670 | 11950 | 38129 | 43212 | |||
TH | M | W | 3080 | 3800 | 12150 | 13770 | |
SH | W | 2430 | 3000 | 9600 | 10878 | ||
TH | L | W | 2400 | 2960 | 9450 | 10710 | |
SH | W | 1950 | 2430 | 7749 | 8782 | ||
heating capacity | H | W | 5700 | 7050 | 22500 | 25500 | |
M | W | 4400 | 5430 | 17300 | 19600 | ||
L | W | 3450 | 4260 | 13600 | 15400 | ||
noise | H | 0Pa | dB(A) | 41 | 43 | 53 | 54 |
power input | H | 0Pa | W | 36 | 41 | 115 | 125 |
waterflow volume | m3/h | 0.65 | 0.81 | 2.58 | 2.92 | ||
water pressure dropping | kPa | 22 | 28 | 51 | 58 | ||
dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
coil | type | ||||||
dimension of water drain pipe | mm | ¢26 | ¢26 | ¢26 | ¢26 | ||
net dimension | drained by pump | L×W×H mm | 590*590*314 | 944*944*316 | |||
drained by nature | 590*590*412 | 944*944*414 | |||||
net weight | drained by pump | kg | 20 | 20 | 41 | 41 | |
drained by nature | 21.5 | 21.5 | 43 | 43 | |||
Testing condition: 2-tube system Cooling Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC Entering/out water temperature: 7ºC/ 12℃ Heating Entering air temperature: 20ºC Entering water temperature: 60ºC, Same water flow rate as for the cooling |
Features
1. Four side air blowing, which can uniform temperature distribution in the room
2. Electrostatic dust sanitizer is optional
3 Fresh air can be input from outside
4 Standard with brushless DC motor
5 Can connect to duct and link with diffuser
Our advantages
1 Customizable metal grille air inlet design, easy to fit with the decoration style.
2 All the key parts are easy to maintain from the air inlet grille
3 The models with big air volume is good for the projects which have large space
Product Applications
If product is installed in spaces with suspended ceilings, such as offices, it can have four air outlets connected to air ducts to supply air to different rooms. In spaces without suspended ceilings, such as factories and workshops, installation without ducts can be used. This product has a long air supply distance, uniform airflow organization, and low installation cost.
TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | |||||||
PERFORMANCE OF 4-SIDE AIR FLOWING TYPE FAN COIL | |||||||
model(2 tube system) | DC-MFP-68FM-Q | DC-MFP-85FM-Q | DC-MFP-272FM-Q | DC-MFP-300FM-Q | |||
power supply | 220V~,50Hz | ||||||
air volume | H | m3/h | 680 | 850 | 2720 | 3000 | |
M | 520 | 660 | 2040 | 2300 | |||
L | 370 | 430 | 1360 | 1600 | |||
static pressure | Pa | 0 | 0 | 0 | 0 | ||
cooling capacity | TH | H | W | 3800 | 4700 | 15000 | 17000 |
BTU/h | 12966 | 14767 | 47130 | 53414 | |||
SH | W | 2830 | 3500 | 11175 | 12665 | ||
BTU/h | 9670 | 11950 | 38129 | 43212 | |||
TH | M | W | 3080 | 3800 | 12150 | 13770 | |
SH | W | 2430 | 3000 | 9600 | 10878 | ||
TH | L | W | 2400 | 2960 | 9450 | 10710 | |
SH | W | 1950 | 2430 | 7749 | 8782 | ||
heating capacity | H | W | 5700 | 7050 | 22500 | 25500 | |
M | W | 4400 | 5430 | 17300 | 19600 | ||
L | W | 3450 | 4260 | 13600 | 15400 | ||
noise | H | 0Pa | dB(A) | 41 | 43 | 53 | 54 |
power input | H | 0Pa | W | 36 | 41 | 115 | 125 |
waterflow volume | m3/h | 0.65 | 0.81 | 2.58 | 2.92 | ||
water pressure dropping | kPa | 22 | 28 | 51 | 58 | ||
dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
coil | type | ||||||
dimension of water drain pipe | mm | ¢26 | ¢26 | ¢26 | ¢26 | ||
net dimension | drained by pump | L×W×H mm | 590*590*314 | 944*944*316 | |||
drained by nature | 590*590*412 | 944*944*414 | |||||
net weight | drained by pump | kg | 20 | 20 | 41 | 41 | |
drained by nature | 21.5 | 21.5 | 43 | 43 | |||
Testing condition: 2-tube system Cooling Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC Entering/out water temperature: 7ºC/ 12℃ Heating Entering air temperature: 20ºC Entering water temperature: 60ºC, Same water flow rate as for the cooling |