Discover custom decorative fan coil units that blend HVAC performance with modern interior design. Conceal bulky hardware and optimize comfort.
Compare high wall vs floor standing fan coil units to optimize HVAC design. Explore the MECO MFP-68BM-C for efficient, space-saving cooling.
Discover the MECO Auto Swing Fan Coil Unit. Eliminate hot and cold spots with quiet, energy-efficient, remote-controlled climate control.
Discover the MECO High Wall Mounted Fan Coil Unit for quiet, safe, and efficient climate control in hotels, apartments, and production spaces.
Discover how a chilled water split type fan coil unit provides efficient, low-noise HVAC climate control for commercial and residential spaces.
Discover the MECO decorative fan coil unit. This sleek, ultra-slim 145mm system delivers quiet, efficient heating and cooling for modern interiors.
Upgrade your space with decorative fan coil units blending modern aesthetics and powerful climate control. Discover the quiet, efficient MECO model.
Discover decorative fan coil units that blend high-end design with climate control. Explore slim, low-noise HVAC solutions for modern interiors.
Specify fan coil units with confidence. Guide to acoustics, EC motors, and drainage to prevent costly HVAC failures and optimize comfort.
Compare fan coil units vs air handling units: a vendor-neutral framework to select the right HVAC system for zoning, IAQ, and cost—avoid over-engineering or inadequate ventilation.
Struggling with HVAC changeover seasons? Our 2-pipe vs 4-pipe fan coil comparison reveals how to balance upfront cost and long-term tenant comfort.
Ceiling concealed vs cassette fan coil units: compare aesthetics, acoustics, & maintenance to select the perfect HVAC for your commercial space.
Cut hotel HVAC noise with data-driven specs, not marketing claims. Learn acoustic metrics and low-noise fan coil selection for silent rooms.
Water leakage from ceiling-mounted HVAC equipment is a building manager's nightmare. A single drip can stain expensive ceiling tiles, damage interior finishes, create slip hazards, and lead to mold growth that affects indoor air quality. For commercial spaces such as hotels, offices, hospitals, and
In a hospital environment, the HVAC system is not merely a matter of occupant comfort—it is a critical component of infection prevention. Nowhere is this more true than in clean rooms, operating theaters, intensive care units (ICUs), isolation wards, and pharmaceutical preparation areas. For these s
Selecting the optimal location for a Floor Standing Concealed Type Fan Coil Unit is one of the most critical decisions in any HVAC system design. The placement of these units directly affects thermal comfort, energy efficiency, equipment longevity, maintenance accessibility, and even property aesthe
How to Clean the Drain Pan of a Concealed Fan Coil Unit?A water stain spreading across a ceiling tile is one of the most dreaded sights for any facility manager or building owner. In hotels, office buildings, hospitals, and residential complexes, water dripping from a Concealed Fan Coil Unit not onl
How to Reduce Vibration Noise in Ducted Fan Coil Units?Excessive vibration noise from a Ducted Fan Coil Units is one of the most frequent complaints in commercial and residential HVAC systems. In hotels, office buildings, hospitals, and apartment complexes, constant rattling, humming, or rumbling fr
Selecting the correct static pressure is one of the most critical—but often misunderstood—steps when designing an HVAC system using a ceiling conceal duct type fan coil unit. In commercial buildings, hotels, hospitals, offices, and residential developments, these units are widely used for their quiet operation, space-saving installation, and flexible air distribution. However, even the most advanced fan coil unit cannot perform as intended if static pressure is improperly selected.
When an HVAC project falls behind schedule, the reason is rarely the equipment alone—it’s the installation details that quietly add hours, create rework, and increase commissioning risk. In many commercial and residential developments, the ceiling conceal duct type fan coil unit is chosen specifically because it delivers comfortable, quiet air distribution while keeping the mechanical system out of sight. But concealment has a trade-off: installers work in tight ceiling voids, coordinate with multiple trades, and fight for every millimeter of clearance.
| Availability: | |
|---|---|
| Quantity: | |
DC3-MTF-60KB
MECO
This slim duct type fan coil unit serves as a ducted HVAC solution designed for ceiling installations with limited space. The unit connects to round ductwork to deliver conditioned air across extended distances, supporting installation in areas where standard ceiling units do not fit. Two standard models are available, DC3-MTF-30KB and DC3-MTF-60KB, covering airflow capacities from 300 to 600 m³/h. External static pressure ranges from 12-50 Pa, enabling flexible duct routing for various room layouts. The unit operates with a brushless DC motor and includes an optional condensate water pump for drainage flexibility.
The unit features a reduced footprint that fits into shallow ceiling plenum spaces. The circular air outlet and inlet connections match standard round duct diameters, allowing installers to integrate the unit with existing ductwork without custom fabrication. Both water inlet and outlet connections use ZG3/4" threads, a common specification in commercial piping systems.
Each unit is equipped with a brushless DC motor driving the centrifugal fan assembly. Motor power input measures 20 W for the 30KB model and 40 W for the 60KB model at high speed. The motor supports three fan speed settings (high, medium, low) to match different load requirements throughout operating hours.
A condensate water pump is available as an add-on configuration for projects where gravity drainage is not feasible. The standard drain pipe connection measures ø26 mm, compatible with common HVAC drainage piping.
Cooling capacity ranges from 765 W to 3600 W (total heat) across both models and three speed settings, with corresponding sensible heat values listed in the specification table. Heating capacity ranges from 1235 W to 5800 W. All performance values are measured under standard rating conditions.
High-speed noise levels are measured at 34 dB(A) for model DC3-MTF-30KB and 36 dB(A) for model DC3-MTF-60KB. These values make the unit suitable for spaces where low background noise is required.
The heat exchanger uses hydrophilic aluminum fins paired with copper tubes. Maximum working pressure is rated at 1.6 MPa for both models, conforming to standard hydronic system requirements. Waterflow volume at high speed is 0.31 m³/h (30KB) and 0.62 m³/h (60KB), with pressure dropping at 21 kPa and 30 kPa respectively.
This ducted fan coil unit is specified for commercial and institutional buildings where ceiling depth is constrained. Common installations include hotel guest rooms, hospital patient rooms, small office suites, retail fitting rooms, and corridor zones. The ducted configuration also supports applications where supply air must be routed away from the unit location to multiple discharge points.
Parameter | Unit | DC3-MTF-30KB | DC3-MTF-60KB | |
Model | DC3-MTF-30KB | DC3-MTF-60KB | ||
Power supply | 220V - 50Hz | 220V - 50Hz | ||
Air volume | H | m³/h | 300 | 600 |
M | m³/h | 180 | 360 | |
L | m³/h | 100 | 200 | |
Static pressure | Pa | 12-50 | 12-50 | |
TH | W | 1800 | 3600 | |
BTU/h | 6142 | 12283 | ||
SH | W | 1301 | 2600 | |
Cooling capacity (H) | BTU/h | 4439 | 8871 | |
TH | W | 1300 | 2630 | |
BTU/h | 4439 | 8981 | ||
Cooling capacity (M) | SH | W | 950 | 1945 |
BTU/h | 3242 | 6635 | ||
TH | W | 765 | 1550 | |
Cooling capacity (L) | SH | W | 485 | 990 |
BTU/h | 1655 | 3378 | ||
Heating capacity | H | W | 2900 | 5800 |
M | W | 2080 | 4180 | |
L | W | 1235 | 3490 | |
Noise | High speed | dB(A) | 34 | 36 |
Power input | High speed | W | 20 | 40 |
Waterflow volume | High speed | m³/h | 0.31 | 0.62 |
Pressure dropping | kPa | 21 | 30 | |
Water tube connection (inlet) | ZG3/4" | ZG3/4" | ||
Water tube connection (outlet) | ZG3/4" | ZG3/4" | ||
Coil | style | Hydrophilic aluminum fin to wear copper tube | Hydrophilic aluminum fin to wear copper tube | |
Maximum working pressure | MPa | 1.6 | 1.6 | |
Condensing water pipe | mm | ø26mm | ø26mm | |
Net dimension | L×W×H | mm | 580×420×235 | 580×710×235 |
Net weight | kg | 16.5 | 21.5 |
Model DC3-MTF-30KB has a net height of 235 mm, and model DC3-MTF-60KB shares the same height dimension. Ceiling plenum depth must accommodate the unit body plus insulation and duct connection clearance.
Yes, both the air supply and return sides use circular connections designed for standard duct attachment. External static pressure of 12-50 Pa supports short to medium duct runs.
No, the condensate water pump is an optional component. Projects with gravity drainage do not require the pump add-on.
Both inlet and outlet water connections are ZG3/4" threaded ports, matching standard hydronic system fittings.
Standard units have fixed piping side orientation. Project-specific orientation requirements should be specified at the time of order confirmation.