The central air conditioning system consists of three parts: air ducts, air duct accessories and components, and end equipment and components of the air conditioning system.
Aluminum zinc plates have become increasingly popular in various industries due to their numerous benefits and applications. In this article, we will explore the advantages of using aluminum zinc plates, such as their exceptional durability and resistance to corrosion. We will also delve into the wi
The overflow of condensate from fan coil units is a common malfunction of centralized air conditioning systems in summer, which often occurs in hot and humid weather and can cause unnecessary damage to air-conditioned rooms.
When it comes to selecting the right DC motor for your application, longevity and performance are two crucial factors to consider. Understanding the key features that contribute to both longevity and performance can help you make an informed decision. In this article, we will explore the standard fe
In the world of modern appliances, space-saving design has become a key consideration for consumers. One innovative solution that has gained popularity is the integration of drain pumps into various home appliances. This article explores the numerous advantages of drain pump integration, focusing on
Are you looking for cost-effective solutions for your installation projects? Optional 3-way valves could be the answer you've been searching for. In this article, we will explore the advantages of using optional 3-way valves, including increased efficiency, reduced maintenance costs, and improved co
In a world where space is a premium, optimizing space usage has become a top priority for many individuals and businesses alike. One innovative solution that has gained popularity is the specially designed slim body, which offers a range of benefits that go beyond just saving space. From practical e
When it comes to HVAC systems, the shape of air inlets and outlets can greatly impact the installation process. In this article, we will explore the advantages of using round air inlets and outlets, focusing on how they simplify the installation process. By delving into case studies and examples, we
Fan coil unit is one of the core components in central air conditioning systems, mainly responsible for regulating indoor temperature and humidity to provide a comfortable indoor environment. Understanding the relationship between air volume, static pressure, power, and motor speed is crucial for th
MECO focuses on the R&D and manufacturing of fan coil unit product and light commercial air-conditioner. We are doing OEM for more than 200 famous central air conditioner enterprises in China, now the company is the preferred of OEM manufacturer for cassette units in China. At the same time, our pro
We can provide customized design for the appearance of packaging carton boxes, customized design for supporting printed products, silk screen printing of machine body trademarks, and pasting of customer trademarks. We provide various control solutions for customers to choose from regarding the produ
MECO Cassette Type Fan Coil Unit Used At Yantai School Land Cooperation Demonstration BaseIn this case, the cassette fan coil unit adopts an extremely simple installation, and the surrounding air outlet allows it to meet the refrigeration and air supply needs of such commercial places very well. The
Availability: | |
---|---|
Quantity: | |
Features
1. 75pa~30pa static pressure, long distance air supply
2. Integrated models 1020~2720m³/h
3. E-heater in optional
4 use DC brushless motor
5 Fresh air can be input from outside
Our advantages
1 Classical elegant design. Aluminized zinc plate galvanized sheet, beautiful appearance. High corrosion resistance.
2 Big diameter fan, big air volume, low noise
3 Circular air duct interface is optional. Which can reduce the installation cost
Product Applications
The medium static pressure ducted type fan coil unit suitable for installation environments that require a certain length of air supply. It can connect air ducts to supply air to every place that needs it.
TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | ||||||||
Performance of high static pressure duct type fan coil unit(MAW series,DC motor ,2 pipe system) | ||||||||
model | unit | DC-MFP-102MAW | DC-MFP-136MAW | DC-MFP-170MAW | DC-MFP-204MAW | DC-MFP-238MAW | DC-MFP-272MAW | |
High speed | m3/h | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 | |
Low speed | m3/h | 360 | 480 | 600 | 720 | 840 | 960 | |
Cooling capacity | High speed kW | TH | 6.6 | 8.2 | 10.2 | 11.9 | 13.9 | 15.1 |
SH | 5 | 6.2 | 7.7 | 8.9 | 10.4 | 11.3 | ||
Low speed kW | TH | 2.8 | 3.4 | 4.3 | 5 | 5.8 | 6.3 | |
SH | 2 | 2.5 | 3.1 | 3.6 | 4.2 | 4.6 | ||
Heating capacity | High speed kW | 10.6 | 13.2 | 16.4 | 19.2 | 22.4 | 24.3 | |
Low speed kW | 4.5 | 5.5 | 6.9 | 8.1 | 9.3 | 10.1 | ||
Noise | dB(A) | 48 | 50 | 54 | 56 | 58 | 60 | |
Water volume | m3/h | 1.13 | 1.4 | 1.74 | 2.03 | 2.37 | 2.58 | |
Static pressure | Pa | 75 | 75 | 75 | 75 | 75 | 75 | |
Water pressure dropping | kPa | 25 | 30 | 32 | 35 | 40 | 55 | |
fan | type | double inlet forward-curve centrifugal fan | ||||||
quantity | 2 | 3 | 4 | |||||
Motor | type | DC brushless motor | ||||||
quantity | 1 | 1 | 2 | 2 | 2 | 2 | ||
power supply | 220V~ 50Hz 1Ph | |||||||
power input(w) | 110 | 155 | 200 | 230 | 270 | 310 | ||
Coil | type | Copper tube coat aluminum fin | ||||||
working pressure | 1.6MPa | |||||||
Pipe connection | water inlet | 3/4" | ||||||
water outlet | 3/4" | |||||||
water drainage | 3/4" | |||||||
dimension(mm) | 1090*624*275 | 1090*624*275 | 1350*624*275 | 1350*624*275 | 1610*624*275 | 1610*624*275 | ||
net weight(kg) | ||||||||
testing condition: | ||||||||
2 PIPE SYSTEM | ||||||||
REFERENCE CONDITIONS | ||||||||
Cooling nominal condition: | ||||||||
indoor air temperature:27℃/19.5℃ DB/WB | ||||||||
water temperature: 7℃/12℃, at maximum speed | ||||||||
Heating nominal condit | ||||||||
indoor air temperature: 21℃/15℃ DB/WB | ||||||||
water inlet temperature: 60℃, at maximum speed, | ||||||||
with the same water flow as in cooling. |
Features
1. 75pa~30pa static pressure, long distance air supply
2. Integrated models 1020~2720m³/h
3. E-heater in optional
4 use DC brushless motor
5 Fresh air can be input from outside
Our advantages
1 Classical elegant design. Aluminized zinc plate galvanized sheet, beautiful appearance. High corrosion resistance.
2 Big diameter fan, big air volume, low noise
3 Circular air duct interface is optional. Which can reduce the installation cost
Product Applications
The medium static pressure ducted type fan coil unit suitable for installation environments that require a certain length of air supply. It can connect air ducts to supply air to every place that needs it.
TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | ||||||||
Performance of high static pressure duct type fan coil unit(MAW series,DC motor ,2 pipe system) | ||||||||
model | unit | DC-MFP-102MAW | DC-MFP-136MAW | DC-MFP-170MAW | DC-MFP-204MAW | DC-MFP-238MAW | DC-MFP-272MAW | |
High speed | m3/h | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 | |
Low speed | m3/h | 360 | 480 | 600 | 720 | 840 | 960 | |
Cooling capacity | High speed kW | TH | 6.6 | 8.2 | 10.2 | 11.9 | 13.9 | 15.1 |
SH | 5 | 6.2 | 7.7 | 8.9 | 10.4 | 11.3 | ||
Low speed kW | TH | 2.8 | 3.4 | 4.3 | 5 | 5.8 | 6.3 | |
SH | 2 | 2.5 | 3.1 | 3.6 | 4.2 | 4.6 | ||
Heating capacity | High speed kW | 10.6 | 13.2 | 16.4 | 19.2 | 22.4 | 24.3 | |
Low speed kW | 4.5 | 5.5 | 6.9 | 8.1 | 9.3 | 10.1 | ||
Noise | dB(A) | 48 | 50 | 54 | 56 | 58 | 60 | |
Water volume | m3/h | 1.13 | 1.4 | 1.74 | 2.03 | 2.37 | 2.58 | |
Static pressure | Pa | 75 | 75 | 75 | 75 | 75 | 75 | |
Water pressure dropping | kPa | 25 | 30 | 32 | 35 | 40 | 55 | |
fan | type | double inlet forward-curve centrifugal fan | ||||||
quantity | 2 | 3 | 4 | |||||
Motor | type | DC brushless motor | ||||||
quantity | 1 | 1 | 2 | 2 | 2 | 2 | ||
power supply | 220V~ 50Hz 1Ph | |||||||
power input(w) | 110 | 155 | 200 | 230 | 270 | 310 | ||
Coil | type | Copper tube coat aluminum fin | ||||||
working pressure | 1.6MPa | |||||||
Pipe connection | water inlet | 3/4" | ||||||
water outlet | 3/4" | |||||||
water drainage | 3/4" | |||||||
dimension(mm) | 1090*624*275 | 1090*624*275 | 1350*624*275 | 1350*624*275 | 1610*624*275 | 1610*624*275 | ||
net weight(kg) | ||||||||
testing condition: | ||||||||
2 PIPE SYSTEM | ||||||||
REFERENCE CONDITIONS | ||||||||
Cooling nominal condition: | ||||||||
indoor air temperature:27℃/19.5℃ DB/WB | ||||||||
water temperature: 7℃/12℃, at maximum speed | ||||||||
Heating nominal condit | ||||||||
indoor air temperature: 21℃/15℃ DB/WB | ||||||||
water inlet temperature: 60℃, at maximum speed, | ||||||||
with the same water flow as in cooling. |