Discover custom decorative fan coil units that blend HVAC performance with modern interior design. Conceal bulky hardware and optimize comfort.
Compare high wall vs floor standing fan coil units to optimize HVAC design. Explore the MECO MFP-68BM-C for efficient, space-saving cooling.
Discover the MECO Auto Swing Fan Coil Unit. Eliminate hot and cold spots with quiet, energy-efficient, remote-controlled climate control.
Discover the MECO High Wall Mounted Fan Coil Unit for quiet, safe, and efficient climate control in hotels, apartments, and production spaces.
Discover how a chilled water split type fan coil unit provides efficient, low-noise HVAC climate control for commercial and residential spaces.
Discover the MECO decorative fan coil unit. This sleek, ultra-slim 145mm system delivers quiet, efficient heating and cooling for modern interiors.
Upgrade your space with decorative fan coil units blending modern aesthetics and powerful climate control. Discover the quiet, efficient MECO model.
Discover decorative fan coil units that blend high-end design with climate control. Explore slim, low-noise HVAC solutions for modern interiors.
Specify fan coil units with confidence. Guide to acoustics, EC motors, and drainage to prevent costly HVAC failures and optimize comfort.
Compare fan coil units vs air handling units: a vendor-neutral framework to select the right HVAC system for zoning, IAQ, and cost—avoid over-engineering or inadequate ventilation.
Struggling with HVAC changeover seasons? Our 2-pipe vs 4-pipe fan coil comparison reveals how to balance upfront cost and long-term tenant comfort.
Ceiling concealed vs cassette fan coil units: compare aesthetics, acoustics, & maintenance to select the perfect HVAC for your commercial space.
Cut hotel HVAC noise with data-driven specs, not marketing claims. Learn acoustic metrics and low-noise fan coil selection for silent rooms.
Water leakage from ceiling-mounted HVAC equipment is a building manager's nightmare. A single drip can stain expensive ceiling tiles, damage interior finishes, create slip hazards, and lead to mold growth that affects indoor air quality. For commercial spaces such as hotels, offices, hospitals, and
In a hospital environment, the HVAC system is not merely a matter of occupant comfort—it is a critical component of infection prevention. Nowhere is this more true than in clean rooms, operating theaters, intensive care units (ICUs), isolation wards, and pharmaceutical preparation areas. For these s
Selecting the optimal location for a Floor Standing Concealed Type Fan Coil Unit is one of the most critical decisions in any HVAC system design. The placement of these units directly affects thermal comfort, energy efficiency, equipment longevity, maintenance accessibility, and even property aesthe
How to Clean the Drain Pan of a Concealed Fan Coil Unit?A water stain spreading across a ceiling tile is one of the most dreaded sights for any facility manager or building owner. In hotels, office buildings, hospitals, and residential complexes, water dripping from a Concealed Fan Coil Unit not onl
How to Reduce Vibration Noise in Ducted Fan Coil Units?Excessive vibration noise from a Ducted Fan Coil Units is one of the most frequent complaints in commercial and residential HVAC systems. In hotels, office buildings, hospitals, and apartment complexes, constant rattling, humming, or rumbling fr
Selecting the correct static pressure is one of the most critical—but often misunderstood—steps when designing an HVAC system using a ceiling conceal duct type fan coil unit. In commercial buildings, hotels, hospitals, offices, and residential developments, these units are widely used for their quiet operation, space-saving installation, and flexible air distribution. However, even the most advanced fan coil unit cannot perform as intended if static pressure is improperly selected.
When an HVAC project falls behind schedule, the reason is rarely the equipment alone—it’s the installation details that quietly add hours, create rework, and increase commissioning risk. In many commercial and residential developments, the ceiling conceal duct type fan coil unit is chosen specifically because it delivers comfortable, quiet air distribution while keeping the mechanical system out of sight. But concealment has a trade-off: installers work in tight ceiling voids, coordinate with multiple trades, and fight for every millimeter of clearance.
| Availability: | |
|---|---|
| Quantity: | |
The ceiling floor type fan coil unit is a decorative exposed-mount HVAC terminal device that supports three installation configurations: ceiling-suspended, floor-standing, and wall-mounted. The unit range covers air volumes from 340 m³/h to 2380 m³/h across eight model sizes, enabling capacity matching for rooms of different dimensions. The exposed casing design eliminates the requirement for a suspended ceiling plenum, making the unit suitable for spaces with limited ceiling height or where ductwork installation is impractical. Applications include hotel lobbies, restaurant dining areas, small office suites, retail showrooms, and residential common areas where visible units with finished appearance are acceptable.
Parameter | Unit | MFP-51ZDM | MFP-68ZDM | MFP-85ZDM | MFP-102ZDM | MFP-136ZDM | MFP-170ZDM | MFP-204ZDM | MFP-238ZDM | ||
Power supply | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | 220V, 50Hz, 1Ph | |||
Air volume | High | m³/h | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium | m³/h | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | ||
Low | m³/h | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | ||
Static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
Cooling capacity (Total, High) | W | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | ||
Cooling capacity (Sensible, High) | W | 1990 | 2730 | 3174 | 4261 | 5385 | 6746 | 8109 | 9062 | ||
Heating capacity (High) | W | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | ||
Noise level (High, 0Pa) | dB(A) | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 51 | ||
Power input (High, 0Pa) | W | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | ||
Water flow volume | m³/h | 0.46 | 0.62 | 0.77 | 0.93 | 1.23 | 1.54 | 1.85 | 2.16 | ||
Water pressure drop | kPa | 11.8 | 13.6 | 21 | 23 | 25 | 32 | 33 | 38 | ||
Water connection (inlet/outlet) | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
Coil type | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | Copper tube with hydrophilic aluminum fin | |||
Maximum working pressure | MPa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | ||
Drain pipe size | mm | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ||
Unit dimension (L×W×H) | mm | 905×673×243 | 905×673×243 | 905×673×243 | 1288×673×243 | 1288×673×243 | 1288×673×243 | 1672×673×243 | 1672×673×243 | ||
Unit weight | kg | 26 | 28 | 30 | 38 | 40 | 42 | 45 | 45 |
The cooling and heating coil consists of copper tubes with hydrophilic aluminum fins. The hydrophilic fin coating reduces water droplet retention on fin surfaces during dehumidification operation, supporting consistent airflow passage through the coil. The 2-pipe system configuration uses a single coil for both chilled water cooling and hot water heating modes. The coil assembly is rated for a maximum working pressure of 1.6 MPa, covering standard commercial HVAC system pressure ranges. A 4-pipe system configuration with separate cooling and heating coils is available as an option for projects requiring simultaneous heating and cooling capability.
A centrifugal fan design delivers airflow across three speed settings — high, medium, and low — selectable by the user. The auto-swing louver function adjusts the discharge air direction vertically, distributing conditioned air across a wider area of the room. The 0Pa external static pressure rating indicates that the unit is designed for direct room air discharge without connected ductwork. Noise levels range from 39 dB(A) for the smallest model to 51 dB(A) for the largest model at high fan speed.
The outer casing is formed with rounded edge contours for exposed installation appearance. The unit includes an integrated drain pan for condensate collection during cooling operation, with a ¢26 mm drain pipe connection for condensate line attachment. Built-in water valves are available as an optional feature, reducing the number of external piping components required during installation.
The unit supports three mounting methods to accommodate different space conditions. Ceiling-suspended installation positions the unit below the ceiling structure with visible casing, suitable for rooms without suspended ceiling plenum. Floor-standing installation places the unit on the floor near exterior walls, applicable where ceiling mounting is structurally unavailable. Wall-mounted installation attaches the unit directly to wall surfaces, saving floor space in smaller rooms.
Standard units include an infrared remote controller for individual room operation, with fan speed selection, mode switching, and temperature setpoint adjustment. For centralized facility management, the unit supports Modbus interface connection to building automation systems, enabling group control and monitoring across multiple units in a single property.
The ceiling floor type fan coil unit installs in spaces where concealed ducted systems are not feasible due to ceiling height limitations or renovation constraints. Common commercial applications include hotel public areas, restaurant dining spaces, small to medium office rooms, boutique retail stores, school classrooms, and healthcare waiting areas. The range of eight model sizes allows capacity matching from small individual offices to larger open-plan areas.
A 2-pipe system uses a single coil for both cooling and heating operation, switching between modes as the building system changes water temperature. A 4-pipe system uses separate cooling and heating coils, allowing individual unit selection between heating and cooling independent of other zones. The 4-pipe configuration is available as an option.
Yes, the units support Modbus protocol interface for connection to centralized building automation systems, allowing facility-wide monitoring and control alongside other HVAC equipment.
Built-in water valves are an optional accessory that can be specified during ordering. When selected, they reduce external piping installation work at the project site.
The condensate drain connection measures ¢26 mm. Installers should match this diameter with the building condensate drain piping system.
Each unit operates with three fan speed levels — high, medium, and low — selectable via the included remote controller. The auto-swing function adjusts vertical air discharge direction independently of fan speed settings.